GENERAL INFO
| Model |
DP6000iL |
| Dimensions/Net Weight |
650X475X550mm, 75kg |
| Battery |
LiFePO4, 5376Wh, 105Ah(51.2V), >3000 cycles to 80%+capacity |
| Operating Temperature |
Discharging Temperature: -20ºC~50ºC, Charging Temperature: 0ºC~45ºC |
| Transfer Time |
≤10ms(UPS Mode), ≤20ms(Appliances Mode) |
| Interactive Interface |
LCD Panel / APP |
| Optional Function |
Charging Input: Low-voltage Solar / EV Charger / Wind |
OUTPUT
| AC Output |
Rated Power |
6000VA @220~240V, 5000VA @100~120V |
| Peak Power |
12000VA / 10000VA |
| Output Waveform |
Pure-Sine Wave, THD<3% |
| Rated Voltage |
100/110/120V, 220/230/240V |
| Rated Frequency |
50/60Hz |
| DC Output |
Cigarette Lighter Port |
12V/10A |
| 5521 Port |
12V/6A |
| USB |
5V/3.1A, QC3.0(5V/3.4A, 9V/2A, 12V/1.5A) |
| Type-C |
PD60W/100W(5V/3A, 9V/3A, 12V/3A, 15V/3A, 20V/3A, 20V/5A) |
CHARGING INPUT
| AC |
Wall Outlet & AC Generator |
220~240VAC Output |
100~250VAC@Appliances Mode, 180~250VAC@UPS Mode
16A MAX, Max. 3600W, 2 hours fully charged |
| 100~120VAC Output |
90~130VAC
16A MAX, Max. 1800W, 4 hours fully charged |
| High-voltage Solar |
MPPT Control System |
220~240VAC Output |
80~450VDC 27A MAX, Max. 6000W, 1 hours fully charged
Solar energy can feed to grid |
| 100~120VAC Output |
120~450VDC 22A MAX, Max. 5000W, 1.5 hours fully charged
Solar energy can feed to grid |
| Low-voltage Solar(1) |
MPPT Control System |
10~150VDC, Max. 2000W, 3 hours fully charged |
| EV Charger(1) |
Mennekes IEC 62196(Type 2)
SAE J1772(Type 1)
GB/T 20234 |
220~240VAC Output |
100~250VAC@Appliances Mode, 180~250VAC@UPS Mode
32A MAX, Max. 6000W, 1 hours fully charged |
| 100~120VAC Output |
90~130VAC
50A MAX, Max. 5000W, 1.5 hours fully charged |
| Wind(1) |
3AC Port |
3AC 48~60V, Max. 2000W, 3 hours fully charged |
|
There are no reviews yet.